Mitsubishi Electric Air Conditioner P2 / P9 Error Code
Indoor coil temperature sensor fault. What it means, which models show it, and how to clear it, easiest fix first.
Mitsubishi ElectricAll Mitsubishi Electric air conditioner codes
One of the temperature sensors on the indoor unit's refrigerant pipes is reading abnormally. P2 refers to the liquid pipe sensor (TH2) and P9 to the coil (condenser/evaporator) pipe sensor (TH5).
Compatible models
Mitsubishi Electric doesn't publish a model list for this code; it appears on Mitsubishi Electric air conditioners with a digital display. Check your owner's manual.
Also shown as
These check codes appear on wired wall controllers, mainly with P-series, Mr. Slim and ducted or ceiling units; wall-mounted M-series units (MSZ) usually report faults by blinking the OPERATION light instead. The meanings here come from Mitsubishi Electric's Mr. Slim code list for Singapore models and its North American wired-controller manual, and they can differ by series and region, so check your manual.
Difficulty
Try the basic checks, but the usual fix is a technician's job.
How to fix Mitsubishi Electric P2 / P9
Reset the power at the breaker
Switch off the breaker that feeds the air conditioner (some systems have separate breakers for the indoor and outdoor units, so switch off both). Wait about five minutes, switch the power back on and restart the unit to see if the code clears.
Note the full code and model number
If the code returns, write down exactly what the display shows on the wall controller and the model number from the label on the side of the indoor unit. Sensor and board parts differ between models, so this lets the technician bring the right part on the first visit.
When to call a technician
These sensors sit inside the indoor unit, so testing and replacing them is a technician job.
Parts linked to P2 / P9
These are the parts most often behind this code. Tap one to see what it does and the signs it is failing.
- liquid pipe thermistor TH2
- coil pipe thermistor TH5
- indoor control PCB
Order parts by your full model number so they fit.
Frequently asked questions
What does P2 / P9 mean on a Mitsubishi Electric air conditioner?
One of the temperature sensors on the indoor unit's refrigerant pipes is reading abnormally. P2 refers to the liquid pipe sensor (TH2) and P9 to the coil (condenser/evaporator) pipe sensor (TH5).
Which Mitsubishi Electric models show the P2 / P9 code?
Mitsubishi Electric doesn't publish a model list for this code; it appears on Mitsubishi Electric air conditioners with a digital display. Check your owner's manual.
Can I fix Mitsubishi Electric P2 / P9 myself?
Only the basic checks. You can safely try the steps above, but P2 / P9 usually points to a part or fault that needs a technician.
What if P2 / P9 keeps coming back?
A code that returns after a reset and the checks above usually means a part is wearing out. Note when P2 / P9 appears (which cycle, how often) and have your model number ready; it helps a technician bring the right part on the first visit.
Other Mitsubishi Electric air conditioner codes
- Blinking OPERATION lightWall unit's indicator light is flashing
- P1Room air temperature sensor fault
- P4 / P5Drain sensor or drain pump problem
- PAShut down to prevent a water leak
- P6Freeze or overheat protection
- P8Pipe temperature error
- PbIndoor fan motor error
- FbIndoor control board error
- E0-E5Wall controller communication error
- E6 / E7 / E9Indoor and outdoor units aren't communicating
- U1 / UdHigh pressure or overheat protection
- U2Discharge temperature too high or low refrigerant
- U3 / U4Outdoor temperature sensor fault
- U6 / UP / UFCompressor overcurrent
- U8Outdoor fan stopped
- U9 / UHPower supply or current sensor problem
- PLRefrigerant circuit abnormal
Last reviewed 2026-10-19. Codes and steps can vary by model; check your owner's manual.