Home › Gree › Air Conditioners › E9
Gree Air Conditioner E9 Error Code
Condensate overflow protection on Gree air conditioners.
GreeAll Gree air conditioner codes
On GREE units with a factory-installed condensate pump, E9 means the water level in the drain pan rose high enough to trip the overflow protection. The pump has stopped keeping up, usually because the drain line or pump is clogged.
Compatible models
GREE's FAQ ties this code to models with a factory-installed condensate pump. Check your manual to see if yours has one.
Also shown as
On units without a factory-installed condensate pump, GREE lists E9 as a heat-mode status where the indoor fan is delayed, which isn't a fault. Check your manual to see which kind you have.
Difficulty
Most people can clear this one at home with simple checks.
Not sure you are reading the code right? See how to read Gree air conditioner codes.
How to fix Gree E9
Turn the system off
Switch the unit off at the breaker. Water near electrical parts is a reason to cut power at the panel, not at a plug.
Check the drain line outlet
Find where the condensate line leaves the house. Clear any mud, insect nests or kinks you can reach at the end of the line.
Let the pan drain
Give the pan time to empty, then restore power and run the unit in cooling. Watch for E9 over the next hour.
When to call a technician
If E9 returns, have a technician clean the drain pan and pump. The pump sits inside the unit.
Parts linked to E9
These are the parts most often behind this code. Tap one to see what it does and the signs it is failing.
Order parts by your full model number so they fit.
Step-by-step guides for this problem
Frequently asked questions
Which Gree models show the E9 code?
GREE's FAQ ties this code to models with a factory-installed condensate pump. Check your manual to see if yours has one.
Can I fix Gree E9 myself?
Usually, yes. Most E9 problems clear with simple checks you can do at home. Start with the first step above: turn the system off.
Other Gree air conditioner codes
- E6Indoor and outdoor units can't communicate
- E1High pressure protection
- E3Low pressure protection
- E2Indoor coil freeze protection
- E5Over-current protection
- E7Mode conflict between indoor units
- E8High temperature protection from low indoor airflow
- H6Indoor fan airflow fault
- L3Outdoor fan airflow fault
- F1Indoor room temperature sensor fault
- F2Indoor coil sensor fault
- F3Outdoor air temperature sensor fault
- F4Outdoor coil sensor fault
- F5Compressor discharge sensor fault
- H1Defrosting (normal in heat mode)
- H5Power module (IPM) protection
- C5Jumper cap missing or wrong
Last reviewed 2026-10-19. Codes and steps can vary by model; check your owner's manual.