Home › Maytag › Dryers › L2 / F4 E4
Maytag Dryer L2 / F4 E4 Error Code
Low or missing line voltage on an electric dryer on Maytag dryers.
The control sees low or no voltage on the second leg of the 240-volt supply, so the heater may not come on even though the drum turns. Maytag says L2 shows up at initial installation. A tripped half of a double breaker, a blown fuse or a cord hooked up wrong are the usual culprits.
Compatible models
L2 appears on Maytag electric dryers at first installation, per Maytag; Sears PartsDirect lists F4 E4 for Maytag Centennial dryers.
Also shown as
L2 is on Maytag's own list; Sears PartsDirect shows F4 E4 on Centennial dryers as a voltage supply error, meaning the L2 leg of 240 volts is missing. Gas dryers run on 120 volts, so this applies to electric models.
Difficulty
Start with the safe checks below; a worn part may need replacing.
Not sure you are reading the code right? See how to read Maytag dryer codes.
How to fix Maytag L2 / F4 E4
Reset both breakers or replace fuses
Switch the dryer's double breaker fully off and back on, even if it looks fine; one side can trip without the handle moving much. In a fuse box, replace any blown fuse with the same rating.
Check the cord hookup on a new install
If the dryer was just installed, compare the cord connection with the Installation Instructions. Unplug the dryer before removing the terminal block cover on the back. Burned or melted wiring there means stop and get it repaired.
Restart on a heated cycle
Pick a heated Timed Dry cycle and start the dryer. Touch any pad to clear the code. Within a few minutes you should feel warm air at the outside vent.
When to call a technician
Maytag says to call a qualified electrician if the code persists. The outlet should deliver 240 volts on its own circuit, and that has to be tested by someone qualified.
Parts linked to L2 / F4 E4
These are the parts most often behind this code. Tap one to see what it does and the signs it is failing.
Order parts by your full model number so they fit.
Step-by-step guides for this problem
- Dryer Not Heating? Electric and Gas Causes and Safe Fixes
Start with the free checks: a no-heat cycle such as Air Fluff, a tripped half of the 240-volt breaker on electric dryers, or a closed gas valve on gas models.
- Dryer Won't Start? Door, Breaker, Fuse and Switch Checks
Most dryers that won't start have a door that isn't fully latched, a start button that wasn't held for 2 to 5 seconds, a control lock that's on, or a tripped breaker.
Frequently asked questions
Which Maytag models show the L2 / F4 E4 code?
L2 appears on Maytag electric dryers at first installation, per Maytag; Sears PartsDirect lists F4 E4 for Maytag Centennial dryers.
Can I fix Maytag L2 / F4 E4 myself?
Often. The first steps above are safe checks a homeowner can do. If they don't clear L2 / F4 E4, the cause is likely a worn part that needs replacing.
Other Maytag dryer codes
- AF / F4 E3Airflow restricted: check the lint screen and vent
- PFPower failure interrupted the cycle
- ERRDoor isn't closed and latched
- F2 E1A control panel button is stuck
- F2 E4 / F2 E5Control panel internal fault
- F1 E1Main control board fault (motor relay)
- F1 E3 / F1 E4Control unit or wiring problem
- F3 E1Exhaust thermistor failure
- F3 E2Moisture sensor failure
- F3 E3Inlet thermistor failure
- F4 E1 / F4 E2Heater relay failure
- F6 E2 / F6 E3Communication failure between boards
- F7 E1Motor system error