Home › Maytag › Dryers › F1 E3 / F1 E4
Maytag Dryer F1 E3 / F1 E4 Error Code
Control unit or wiring problem on Maytag dryers.
Maytag says both codes point to the control unit or the wiring connected to it. Sears PartsDirect adds that F1 E3 means the wrong control board is installed, so it often shows up right after a board replacement.
Compatible models
Maytag doesn't publish a model list for these codes; Sears PartsDirect lists F1 E3 on Maytag Centennial dryers.
Also shown as
For F1 E3, Maytag first suggests touching Power, choosing a cycle and holding Start/Pause; for F1 E4 it uses the 5-minute power reset. Sears PartsDirect lists F1 E3 for Centennial dryers.
Difficulty
Try the basic checks, but the usual fix is a technician's job.
Not sure you are reading the code right? See how to read Maytag dryer codes.
How to fix Maytag F1 E3 / F1 E4
Try a normal restart
Touch Power, choose a cycle, then press and hold Start/Pause. If the dryer won't run, unplug it.
Do the 5-minute reset
With the breaker(s) off for 5 minutes, the control fully restarts. Turn power back on, run Timed Dry and watch for 5 minutes.
Mention any recent repair
If a board was replaced recently and F1 E3 appeared afterward, tell the servicer. The replacement part number may not match your model.
When to call a technician
A code that keeps coming back needs a technician to check the control and its wiring, and to confirm the correct board for your model number.
Parts linked to F1 E3 / F1 E4
These are the parts most often behind this code. Tap one to see what it does and the signs it is failing.
Order parts by your full model number so they fit.
Frequently asked questions
Which Maytag models show the F1 E3 / F1 E4 code?
Maytag doesn't publish a model list for these codes; Sears PartsDirect lists F1 E3 on Maytag Centennial dryers.
Can I fix Maytag F1 E3 / F1 E4 myself?
Only the basic checks. You can safely try the steps above, but F1 E3 / F1 E4 usually points to a part or fault that needs a technician.
Other Maytag dryer codes
- AF / F4 E3Airflow restricted: check the lint screen and vent
- PFPower failure interrupted the cycle
- L2 / F4 E4Low or missing line voltage on an electric dryer
- ERRDoor isn't closed and latched
- F2 E1A control panel button is stuck
- F2 E4 / F2 E5Control panel internal fault
- F1 E1Main control board fault (motor relay)
- F3 E1Exhaust thermistor failure
- F3 E2Moisture sensor failure
- F3 E3Inlet thermistor failure
- F4 E1 / F4 E2Heater relay failure
- F6 E2 / F6 E3Communication failure between boards
- F7 E1Motor system error
Last reviewed 2026-10-20. Codes and steps can vary by model; check your owner's manual.