Home › Air Conditioners › Parts › Temperature sensors (thermistors)
Air Conditioner Temperature sensors (thermistors): What It Does and Signs It's Failing
Small sensors on wires clipped to pipes or sitting in the airflow. The indoor unit has a room air sensor and coil or pipe sensors; the outdoor unit has outdoor air, coil, discharge and compressor sensors.
Who should replace it
Technician job
Related codes
43 error codes on this site point to this part.
How it works
Each sensor's resistance changes with temperature, and the board reads it. If one reads open or shorted, the board usually stops the unit and shows a sensor code.
Signs it is failing
- Sensor codes for a room, coil, pipe, outdoor or discharge sensor
- Unit runs nonstop or shuts off too early
- Wrong room temperature readings
- Freeze-up of the indoor coil
Sensor codes point here first, but most brands also list loose connectors and the control board. High discharge or compressor temperature codes are different: Fujitsu ties those to real overheating from low refrigerant, a restriction or poor outdoor airflow.
Can you replace it yourself?
Reset power and clean the filters; for outdoor sensor codes, clear leaves, snow and debris from around the outdoor unit too. Indoor sensors are behind the front panel and wired to the indoor board. Outdoor sensors are clipped to the pipes and wired into the outdoor unit's electrical compartment, next to the inverter electronics, so testing and replacement belong to a tech.
Buying the right part
Thermistors differ by location and resistance value. The tech will match them to your model.
Error codes linked to the temperature sensors (thermistors)
- U0Low refrigerant or restricted refrigerant flowDaikin
- A5Freeze-up or overheat protectionDaikin
- C4Indoor coil temperature sensor faultDaikin
- C9Indoor room air temperature sensor faultDaikin
- F3Compressor discharge temperature too highDaikin
- F6High pressure in cooling modeDaikin
- E1Short cycling or a sensor fault, depending on modelFriedrich
- E2Stuck button or a sensor fault, depending on modelFriedrich
- E3 / E4Frost probe open or shortedFriedrich
- E5 / E6Room temperature probe open or shortedFriedrich
- 41Room temperature sensor errorFujitsu
- 42Indoor coil temperature sensor errorFujitsu
- 71-74Outdoor unit temperature sensor errorFujitsu
- A1Discharge temperature too highFujitsu
- A3Compressor temperature too highFujitsu
- F1Indoor room temperature sensor faultGree
- F2Indoor coil sensor faultGree
- F3Outdoor air temperature sensor faultGree
- F4Outdoor coil sensor faultGree
- F5Compressor discharge sensor faultGree
- H1Defrosting (normal in heat mode)Gree
- CH01 / CH02 / CH06Temperature sensor faultLG
- EH 60Room temperature sensor faultMidea
- EH 61Indoor coil sensor faultMidea
- EL 0CPossible refrigerant leak detectedMidea
- EC 53Outdoor air temperature sensor faultMidea
- EC 52Outdoor coil sensor faultMidea
- EC 54Compressor discharge sensor faultMidea
- PC 0LToo cold outside to runMidea
- E1Portable AC room temperature sensor faultMidea
- E2Portable AC evaporator sensor faultMidea
- ASWindow AC room temperature sensor faultMidea
- Blinking OPERATION lightWall unit's indicator light is flashingMitsubishi Electric
- P1Room air temperature sensor faultMitsubishi Electric
- P2 / P9Indoor coil temperature sensor faultMitsubishi Electric
- P8Pipe temperature errorMitsubishi Electric
- U2Discharge temperature too high or low refrigerantMitsubishi Electric
- U3 / U4Outdoor temperature sensor faultMitsubishi Electric
- E121Room temperature sensor faultSamsung
- E122 / E123Indoor coil temperature sensor faultSamsung
- E416Compressor running too hotSamsung
- E221 / E231 / E251Outdoor temperature sensor faultSamsung
- E440 / E441Outside temperature beyond operating limitSamsung
Last reviewed 2026-10-19.